CIRCUIT BREAKER
CUTLER HAMMER/EATON
CHF120
1P 20A 120/240V C/B
THERMAL MAGNETIC; 120/240 VAC VOLTAGE RATING; 20 AMPERE CURRENT RATING; 1 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL ALUMINUM/COPPER WIRE; APPROVAL UL 489, CSA C22.2; CH MODEL; FEATURES SWITCHING DUTY RATED, HACR RATED, TRIP INDICATION

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
DISCONNECT SWITCH NON-FUSED PULL-OUT
CUTLER HAMMER/EATON
DPU222R
60A 2P NF 240V AC DISC/PULLOUT
240 VAC 1 PHASE; 60 AMPERE; POWER RATING 10 HP; 2 WIRE; NON FUSIBLE FUSE; NEMA 3R; GALVANIZED STEEL ENCLOSURE; SIZE 5.4 INCH W X 3.152 INCH D X 8.7 INCH H; APPROVAL UL

Show all:  Safety Switch Accessories

 Spec Sheet   |   More Details
CIRCUIT BREAKER
CUTLER HAMMER/EATON
CHF230
2P 30A CB
THERMAL MAGNETIC, COMMON TRIP; 120/240 VAC VOLTAGE RATING; 30 AMPERE CURRENT RATING; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL ALUMINUM/COPPER WIRE; APPROVAL UL 489, CSA C22.2; CH MODEL; FEATURES HACR RATED, TRIP INDICATION

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
METALLIC PULL BOX
HOFFMAN
ASG12X12X6NK
GALV SC BOX-NO K
HEIGHT 12 INCH; WIDTH 12 INCH; DEPTH 6 INCH; STEEL; MATERIAL SPECIFICATION 16/14/12 GAUGE; GALVANIZED; NEMA 1, IP30; WALL MOUNTING; FLAT, SCREW ON COVER; APPROVAL UL 50, CSA; HOFFMAN[R] BRAND; APPLICABLE STANDARD IEC 60529; APPLICATION COMMERCIAL, INDUSTRIAL; PANEL NONE

Show all:  Nema Type 1 Metallic Enclosures, Boxes, Cabinets

 Spec Sheet   |   More Details
MINIATURE BOLT-ON CIRCUIT BREAKER
CUTLER HAMMER/EATON
BAB1020
20A 1P CKT BRKR
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48 VDC, 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING; APPROVAL UL 489, CSA; QUICKLAG[R] BRAND; BAB MODEL

Show all:  Standard Trip Bolt-On Circuit Breakers

 Spec Sheet   |   More Details
METER SOCKET INTERCHANGEABLE UNIT HUB
MILBANK MFG COMPANY
A7517
2" HUB
STANDARD SMALL RL OPENING; 2 INCH CONDUIT

Show all:  Meter Socket & Metering Accessories

 Spec Sheet   |   More Details
METALLIC PULL BOX
HOFFMAN
ASG12X12X4NK
GALV SC BOX-NO K
HEIGHT 12 INCH; WIDTH 12 INCH; DEPTH 4 INCH; STEEL; MATERIAL SPECIFICATION 16/14/12 GAUGE; GALVANIZED; NEMA 1, IP30; WALL MOUNTING; FLAT, SCREW ON COVER; APPROVAL UL 50, CSA; HOFFMAN[R] BRAND; APPLICABLE STANDARD IEC 60529; APPLICATION COMMERCIAL, INDUSTRIAL; PANEL NONE

Show all:  Nema Type 1 Metallic Enclosures, Boxes, Cabinets

 Spec Sheet   |   More Details
CIRCUIT BREAKER
CUTLER HAMMER/EATON
CHF250
2P 50A CB

Show all:  Standard Trip Plug-In Circuit Breakers

 More Details
METALLIC PULL BOX
HOFFMAN
ASG8X8X4NK
GALV SC BOX-NO KO
HEIGHT 8 INCH; WIDTH 8 INCH; DEPTH 4 INCH; STEEL; MATERIAL SPECIFICATION 16/14/12 GAUGE; GALVANIZED; NEMA 1, IP30; WALL MOUNTING; FLAT, SCREW ON COVER; APPROVAL UL 50, CSA; HOFFMAN[R] BRAND; APPLICABLE STANDARD IEC 60529; APPLICATION COMMERCIAL, INDUSTRIAL; PANEL NONE

Show all:  Nema Type 1 Metallic Enclosures, Boxes, Cabinets

 Spec Sheet   |   More Details
CIRCUIT BREAKER
CUTLER HAMMER/EATON
CHF220
2P 20A CB
THERMAL MAGNETIC, COMMON TRIP; 120/240 VAC VOLTAGE RATING; 20 AMPERE CURRENT RATING; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL ALUMINUM/COPPER WIRE; APPROVAL UL 489, CSA C22.2; CH MODEL; FEATURES HACR RATED, TRIP INDICATION

Show all:  Standard Trip Plug-In Circuit Breakers

 Spec Sheet   |   More Details
METALLIC PULL BOX
HOFFMAN
ASG6X6X4NK
GALV SC BOX-NO KO
HEIGHT 6 INCH; WIDTH 6 INCH; DEPTH 4 INCH; STEEL; MATERIAL SPECIFICATION 16/14/12 GAUGE; GALVANIZED; NEMA 1, IP30; WALL MOUNTING; FLAT, SCREW ON COVER; APPROVAL UL 50, CSA; HOFFMAN[R] BRAND; APPLICABLE STANDARD IEC 60529; APPLICATION COMMERCIAL, INDUSTRIAL; PANEL NONE

Show all:  Nema Type 1 Metallic Enclosures, Boxes, Cabinets

 Spec Sheet   |   More Details
ARC FAULT AFCI PLUG-IN CIRCUIT BREAKER
CUTLER HAMMER/EATON
CHFCAF120
1P 20A CT INTPR

Show all:  Arc Fault Afci Plug-In Circuit Breakers

 More Details
WIREWAY CLOSING PLATE
HOFFMAN
F66GCPNK
NMA1 WIREWY END-NO K
LAY IN WIREWAY; SCREW WIREWAY COVER; WIDTH 6 INCH; HEIGHT 6 INCH; NO KNOCKOUT(S); 14/16 GAUGE STEEL; ANSI 61 GRAY POLYESTER; NEMA 1, IP30; APPROVAL UL, CSA; HOFFMAN[R] BRAND; F40G MODEL

Show all:  Wireway General Accessories

 Spec Sheet   |   More Details
MINIATURE BOLT-ON CIRCUIT BREAKER
CUTLER HAMMER/EATON
BAB2020
20A 2P CKT BRKR
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING; APPROVAL UL 489, CSA; QUICKLAG[R] BRAND; BAB MODEL

Show all:  Standard Trip Bolt-On Circuit Breakers

 Spec Sheet   |   More Details
MINIATURE BOLT-ON CIRCUIT BREAKER
CUTLER HAMMER/EATON
BAB2030
30A 2P CKT BRKR
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC, 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL, BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER, LOAD); BOLT ON MOUNTING; APPROVAL UL 489, CSA; QUICKLAG[R] BRAND; BAB MODEL

Show all:  Standard Trip Bolt-On Circuit Breakers

 Spec Sheet   |   More Details